基于 RNA药物 的各种应用于使用上日益增多,无论是为快速上市的西林瓶,还是为求剂量准确性和易用性的预灌装注射器(PFS),其在供应链、冷库(若需要)或生命周期管理等各阶段皆带来了技术上的考虑和挑战。
RNA 封装在脂质纳米粒中,并对容器封闭系统中的微粒显示出高度敏感。身为制药商必须将其在制造方面的挑战纳入考虑。
在深度冷储存的供应链期间
在生命周期管理的期间
确保药品稳定性
整合并管理不同的技术平台(如:脂质纳米粒制剂)
斯蒂瓦那托集团 (Stevanato Group) 能够为 RNA 生产过程提供覆盖整个制药价值链的全面性解决方案。
我们在市场中的独特定位使我们得以成为内包材、机械和分析服务的综合提供者。
斯蒂瓦那托集团 (Stevanato Group) 为 RNA 技术的理想合作伙伴,因为我们通过单一界面提供一步到位的解决方案,缩短上市时间。
经我们研究后,我们的 EZ-fill®ITC 注射器已通过与各项主要挑战相关的所有检测。请看下方结果:
Pre-fillable syringes have several components that compose the system, and deep cold storage is a big challenge to maintaining all the materials' integrity.
Chart: No CO2 was detected in all 30 ITC filled syringes tested through Carbon Dioxide headspace analysis, indicating that no defect allowing CO2 ingress occurred due to any material property changes at -70°C. The controls in both cases performed as expected, showing a substantial ingress of CO2 for the positive control, and no CO2 ingress for the negative controls.
We tested and confirmed no loss of CCI of EZ-fill® ITC syringes after 7 days of storage at -70°C. Tests executed through CO2 Headspace Analysis showed no relevant signals of carbon dioxide ingress after a 1-week freezing cycle whilst also verifying the plunger displacement phenomenon confirming the suitability of EZ-fill® ITC system for mRNA applications.
Low temperature can also affect the functionality of the overall system. Two of the most important parameters that describe the system's functionality are Break Loose and Gliding Force.
Charts: The test showed that freezing storage has no impact on break loose and gliding force, confirming no functional impact from Room Temperature to -40°C.
We tested - after 1-week storage at -40°C - filled ITC syringes and they showed excellent Break Loose and Gliding Force* performance with comparable results before and after freezing storage.
* ISO 11040-4:2015 as a standard reference
We tested the ITC closure unscrew* after 5 cycles at -50° storage with extraordinary results. The test showed no statistical difference in unscrewing torque (Tmax) between the sub-categories, confirming that ITC closure functionality is guaranteed after freezing condition, with no impact on usability for the final user.
Chart: No evidence of difference in unscrewing force for all the 50 ITC syringes tested for each category.
Deep cold storage may stress the glass barrel of a PFS system causing potential system failures.
Chart: Results at Room Temperature and at -40°C are comparable, confirming that freezing did not affect glass resistance to breakage.
Regarding mechanical properties, Burst Test* performed on Stevanato Group ITC syringe did not show difference in glass barrel resistance between -40°C and room temperature storage conditions, confirming good mechanical performances.
* ISO 7458:2004 as standard reference.
Market Insight
Covid-19 and the subsequent rise of mRNA vaccines brought new types of therapies to the market that require storage at deep-cold temperatures down to -80 °C.
Risk
The stress on the glass at these low temperatures increases the chance of vial breakage. The risk of breakage is extremely important to pharmaceutical companies due to the high values od drug cointained.
Need
Increased assurance about the compatibility of glass containers with cold storage conditions is key for pharmaceutical companies.
Solution
In this increasingly complex application, EZ-fill® vials are a proven solution to make life easier for customers. Find out Fina® Vial’s optimal performances with deep-cold drug applications and complex cold-chain requirements for both Mechanical & Container Closure Integrity (CCI) performance
Objective
Identify and determine the impact (if any) on glass vials’ mechanical resistance to Axial Load and Internal Pressure of storage conditions of -80°C over a period of 7 days
Method
Vertical Compression and Burst test
Results
2R Fina® quality glass can withstand a conditioning at -80°C for a prolonged period of time without impacting its mechanical performance.
Objective
Determine CCI during stability at 25°C/60% RH and -80°C at two different time points (T0 and T6 months) over a storage period of 6 months.
Method
Use of Headspace Gas Analysis technique, based on the measurement of the headspace carbon dioxide content in the samples after exposure to a carbon dioxide enriched environment at the target temperatures.
Results
no CO2 detected in all the samples. 2R Fina® vial geometry, in combination with different closure systems, can maintain CCI for a prolonged period of time under the testing conditions
The configurations tested showed no statistically significant difference before and after conditioning.